Other Services

banner_03

Other Services

Water Leak Detection System

The water leak detection cable itself is the sensor. Every centimeter of rugged cable is sensitive to water and when water comes in contact with the cable, even a few millimeters, the system is able to detect the leak and report the location. Typical applications in office buildings include the monitoring of fan coil units, in PAC rooms, data centers, and dedicated monitoring of leaks in electrical switch gear rooms, server rooms, network communications, etc.

Ultrasonic Rodent Repellent System.

Ultrasonic rodent repellents are electronic transmitters of high frequency sound (well above 20 KHz frequency, the upper limit of human audible range). They emit intensive sound at high decibels (Sound pressure) that is audible and painful to pets but is inaudible and harmless to pets, leading them to leave the area protected by the ultrasound. They don’t get killed.

Water Mist System.

Water mist system is one the most advance system in the suppression system. Here as the name suggests we use the water as the medium of extinguishing agent and it consumes about 10% of the water as against the conventional sprinkler system.

Here the water is discharged in the form of very fine tiny droplets. They droplets causes two unique effects viz… cooling effect and oxygen displacement. The operating pressure is normally between 80 bar to 200 bar.

Fire extinguishers.

A fire extinguisher is an active fire protection device used to extinguish or control small fires, often in emergency situations. It is not intended for use in out of control fire.

The Fire extinguishers typically consists of hand held cylindrical pressure vessel containing an agent which can be discharged to extinguish the fire. Depending upon the application we have different type of fire extinguishers like ABC type, CO2 type, water Co2 and clean agents as well.

Automated Barriers.

We offer a wide range of automated barriers for vehicular movement like toll way barriers, parking barriers, bollards, high security gates (slide/swing) and parking management.

We have rising step crash barriers and nail belt barriers for the anti terrorism segment. Flap barriers, swing barriers, full, half and quarter height bi directional turnstiles.

Access control and CCTV system can be integrated with the perimeter protection.

Smoke curtains.

Smoke curtain prevents the movement of smoke and fire from one area to another in a fire by channeling or containing the smoke and heat. They are well suited to most commercial and industrial buildings as they are unobtrusive, moving to their active position only when needed.

These barriers can be fitted with natural or automatic smoke and heat exhaust ventilator system of the building. They can be either manually operated or fully automated incase of any uneventful event.

Pre action systems.
Pre-action fire sprinkler systems employ the basic concept of a dry pipe system in that water is not normally contained within the pipes. The difference, however, is that water is held from piping by an electrically operated valve, known as a pre-action valve. Valve operation is controlled by independent flame, heat, or smoke detection.

Two separate events must happen to initiate sprinkler discharge. First, the detection system must identify a developing fire and then open the pre-action valve. This allows water to flow into system piping, which effectively creates a wet pipe sprinkler system. Second, individual sprinkler heads must release to permit water flow onto the fire.

In some instances, the pre-action system may be set up with a double interlock in which pressurized air or nitrogen is added to system piping. The purpose of this feature is two-fold: first to monitor piping for leaks and second to hold water from system piping in the event of inadvertent detector operation.

State of the art equipment are preferred when it come to serving our clients
cctv

Other services

Water Leak Detection System

The water leak detection cable itself is the sensor. Every centimeter of rugged cable is sensitive to water and when water comes in contact with the cable, even a few millimeters, the system is able to detect the leak and report the location. Typical applications in office buildings include the monitoring of fan coil units, in PAC rooms, data centers, and dedicated monitoring of leaks in electrical switch gear rooms, server rooms, network communications, etc.

Ultrasonic Rodent Repellent System.

Ultrasonic rodent repellents are electronic transmitters of high frequency sound (well above 20 KHz frequency, the upper limit of human audible range). They emit intensive sound at high decibels (Sound pressure) that is audible and painful to pets but is inaudible and harmless to pets, leading them to leave the area protected by the ultrasound. They don’t get killed.

Water Mist System.

Water mist system is one the most advance system in the suppression system. Here as the name suggests we use the water as the medium of extinguishing agent and it consumes about 10% of the water as against the conventional sprinkler system.

Here the water is discharged in the form of very fine tiny droplets. They droplets causes two unique effects viz… cooling effect and oxygen displacement. The operating pressure is normally between 80 bar to 200 bar.

Fire extinguishers.

A fire extinguisher is an active fire protection device used to extinguish or control small fires, often in emergency situations. It is not intended for use in out of control fire.

The Fire extinguishers typically consists of hand held cylindrical pressure vessel containing an agent which can be discharged to extinguish the fire. Depending upon the application we have different type of fire extinguishers like ABC type, CO2 type, water Co2 and clean agents as well.

Automated Barriers.

We offer a wide range of automated barriers for vehicular movement like toll way barriers, parking barriers, bollards, high security gates (slide/swing) and parking management.

We have rising step crash barriers and nail belt barriers for the anti terrorism segment. Flap barriers, swing barriers, full, half and quarter height bi directional turnstiles.

Access control and CCTV system can be integrated with the perimeter protection.

Smoke curtains.

Smoke curtain prevents the movement of smoke and fire from one area to another in a fire by channeling or containing the smoke and heat. They are well suited to most commercial and industrial buildings as they are unobtrusive, moving to their active position only when needed.

These barriers can be fitted with natural or automatic smoke and heat exhaust ventilator system of the building. They can be either manually operated or fully automated incase of any uneventful event.

Pre action systems.

Pre-action fire sprinkler systems employ the basic concept of a dry pipe system in that water is not normally contained within the pipes. The difference, however, is that water is held from piping by an electrically operated valve, known as a pre-action valve. Valve operation is controlled by independent flame, heat, or smoke detection.

Two separate events must happen to initiate sprinkler discharge. First, the detection system must identify a developing fire and then open the pre-action valve. This allows water to flow into system piping, which effectively creates a wet pipe sprinkler system. Second, individual sprinkler heads must release to permit water flow onto the fire.

In some instances, the pre-action system may be set up with a double interlock in which pressurized air or nitrogen is added to system piping. The purpose of this feature is two-fold: first to monitor piping for leaks and second to hold water from system piping in the event of inadvertent detector operation.

Public addressable systems